Tel: 44 (0) 1293 408 123 Fax: 44 (0) 1293 408 125 
 

Multiflash Flash point tester - Mindex Ltd UK

Home Products About us Quotation Contact us
   
Search site  
 
 
   
 
Petroleum Testing
Stanhope Seta
A whole selection of petroleum test equipment to ASTM standards.
Zeltex Inc,
Portable Octane analysers
XOS
Chlorine analysers & Sulfur analysers
Cement/Core PVT Testing
Ergotech
Core analysis, petrophysics & rock mechanicss
Chandler Engineering
PVT, porrositmeters, cement testing equipments
PMAC
Core flood analysis equipments
Refinery analysers
ATAC
Specialising in on-line analytical instrumentation for oil, gasindustries s
Scientific Equipment
Ravenfield
Specialising in high precision viscometers, rheometers and other scientific instruments
Elemental analysis
CHNS-O Analysers | N-Protein Analyser | EA-IRMS Interfaces
Noblegen
Various specialist gas generators
Aurora Instruments
UV spectrophotometers/ Microwave digestion/ spectrometers
Building products
Blockleys paviours
Middle East agents for bricks and paviours
Publications
Journals/ books/ subscriptions
Global magazine/ periodical subscription service
Health and safety
Back supports
Mindex Ltd back support reduce back injury in the workplace
Petrochemicals
Petroleum dyes
Chemical marker for petroleum based products.
 
 
 
34000-0 Seta Multiflash Automatic Flashpoint Tester - Universal Base Unit

The Seta Multiflash fully automatic flash point tester is unique in covering the widest range of test methods. The instrument is configured as a universal base unit with a choice of interchangeable modules that implement Pensky-Martens (A and B), Abel, Cleveland, Tag, Small Scale (Setaflash Rapid Equilibrium), and Equilibrium tests. Each module conforms to the requirements of the appropriate test method and special emphasis has been put on using water baths where these are mandated in test methods.
 
Seta Multiflash - Pensky Martens Flashpoint Tester Part Number 34100-2

Methods

ASTM D93, ASTM E502, BS 2000 Parts 34 & 404, DIN 51 758, EN ISO 2719, EPA 1010A, FTM 791 1102, GB/T 261, IP 34, IP 404, ISO 15267, JIS K2265, NF M07-019

The 34100-2 Pensky Martens module is used with the 34000-0 MultiFlash Universal Base unit. The module conforms precisely to national and international Pensky-Martens Closed Cup standard test methods. It comprises a heated cup and lid, and a DIPS pod (Dipping, Ignition, Pilot, Stirrer) containing the ignitor dipping mechanism, the gas and electric ignitors and a stirrer.

Interchanging the test module is straightforward and completed in just a few minutes and the base unit recognises the module that is connected and instantaneously sets up standard test parameters and calibration data..
 
 
 
Features

* Fully self-contained flash test module

* Exactly conforms to the requirement of test method
* Automatic set up of test parameters
* Gas or electric ignition
* Automatic heating control, ignition & flash detection
* Automatic test results & end of test audible warning
* Centigrade or Fahrenheit temperature display
* Automatic barometric correction

To download a full brochure in pdf format of this product please click here
 
 
Seta Multiflash - Abel Flashpoint Tester Part Number 34200-0

Methods

BS 2000 Part 170, BS 3900 Parts A8 & A9, BS 6664 Parts 1 & 2, EN ISO 13736, IP 170, IP 304 (obs) Parts 1 and 2, IP 491, IP 492, ISO 1523

The 34200-0 Abel module is used with the 34000-0 MultiFlash Universal Base unit. The module conforms precisely to national and international Abel test methods. It comprises a water/air bath, sample cup and lid, temperature probes, flash detector, and a DIPS pod (Dipping, Ignition, Pilot, Stirrer) containing the ignitor dipping mechanism with co-axial gas/electric ignitor, and a stirrer. Interchanging the test module is straightforward and completed in just a few minutes and the base unit recognises the module that is connected and instantaneously sets up standard test parameters and calibration data.
 
 
Features

* Fully self-contained flash test module

* Exactly conforms to the requirement of test method
* Automatic set up of test parameters
* Gas or electric ignition
* Automatic heating control, ignition & flash detection
* Automatic test results & end of test audible warning
* Centigrade or Fahrenheit temperature display
* Automatic barometric correction


To download a full brochure in pdf format of this product please click here
 
 
Seta Multiflash - Cleveland Open Cup Flashpoint Tester Part Number 34300-0

Methods

AASHTO T48, ASTM D92, BS 2000 Parts 36 & 403, DIN 51 376, EN ISO 2592, IP 36, JIS K2265, NF T60-119

The 34300-0 Cleveland module is used with the 34000-0 MultiFlash Universal Base unit. The module conforms precisely to national and international Cleveland open cup test methods.
It comprises a sample cup, temperature probe, flash/fire detector, and a DIPS pod (Sweeping, Ignition, Pilot, Stirrer) containing the ignitor sweeping mechanism with co-axial gas/electric ignitor.

Interchanging the test module is straightforward and completed in just a few minutes and the base unit recognises the module that is connected and instantaneously sets up standard test parameters and calibration data.
 
 
Features

* Fully self-contained flash test module

* Exactly conforms to the requirement of test method
* Automatic set up of test parameters
* Gas or electric ignition
* Automatic heating control, ignition & flash detection
* Automatic test results & end of test audible warning
* Centigrade or Fahrenheit temperature display
* Automatic barometric correction


To download a full brochure in pdf format of this product please click here
 
 
Seta Multiflash - Tag Flashpoint Tester Part Number 34400-0

Methods

ASTM D3934, ASTM D3941, ASTM D56, ASTM E502, FTM 791 1101, IP 304 (obs) Parts 1 and 2, IP 491, IP 492, ISO 1516, ISO 1523, JIS K2265

The 34400-0 TAG module is used with the 34000-0 MultiFlash Universal Base unit.

The module conforms precisely to national and international TAG closed cup test methods. It comprises a water bath, sample cup and lid, temperature probes, flash detector, and a DIPS pod (Dipping, Ignition, Pilot, Stirrer) containing the ignitor dipping mechanism with co-axial gas/electric ignitor, and a stirrer.

Interchanging the test module is straightforward and completed in just a few minutes and the base unit recognises the module that is connected and instantaneously sets up standard test parameters and calibration data..

 
 
Features

* Fully self-contained flash test module

* Exactly conforms to the requirement of test method
* Automatic set up of test parameters
* Gas or electric ignition
* Automatic heating control, ignition & flash detection
* Automatic test results & end of test audible warning
* Centigrade or Fahrenheit temperature display
* Automatic barometric correction


To download a full brochure in pdf format of this product please click here
 
 
 