Search
site |
|
| |
|
|
| |
|
|
 |
|
 |
|
| |
| Petroleum Testing |
|
|
|
A whole selection of
petroleum test equipment to ASTM standards. |
|
|
|
|
Portable Octane
analysers |
|
|
|
|
Chlorine analysers
& Sulfur analysers |
|
| Cement/Core PVT
Testing |
|
Core analysis,
petrophysics & rock mechanicss |
|
|
|
|
PVT, porrositmeters,
cement testing equipments |
|
|
|
|
Core flood analysis
equipments |
|
| Refinery analysers |
|
|
|
Specialising in on-line
analytical instrumentation for oil, gasindustries s |
|
| Scientific
Equipment |
|
|
|
Specialising in high precision viscometers, rheometers and
other scientific instruments |
|
|
|
|
|
|
|
|
Various specialist gas
generators |
|
|
|
|
UV spectrophotometers/
Microwave digestion/ spectrometers |
|
| Building
products |
|
|
|
Middle East agents for
bricks and paviours |
|
| Publications |
|
|
|
Global magazine/ periodical subscription
service |
|
| Health and
safety |
 |
Back supports |
|
|
Mindex Ltd back support reduce back injury in the
workplace |
|
| Petrochemicals |
|
|
|
Chemical marker for petroleum based
products. |
|
|
|
| |
| |
|
|
 |
|
| |
| The
Ravenfield Coldshear viscometer was designed to simulate the standard
low temperature test ASTM D 5293. Development of our compact, low energy
consumption technology has led to the CS-2 . The CS-2 not only correlates with
ASTM D 5293 but is also a full research grade rheometer. |
| |
 |
| |
The
CS-2 Cranking Simulator is the most recent development in the Coldshear range.
It is designed to bring the best of Ravenfield's HTHS experience to Low
Temperature High Shear measurement. In its standard operating mode this
instrument correlates with ASTM D 5293 (formerly ASTM D 2602), but is not
limited to this; using high precision computer control the instrument also
measures under conditions of constant shear rate, constant shear stress and
constant speed. ASTM is currently organising a Round Robin to generate a new
test method.The CS-2 is a self-contained, single unit instrument requiring no
extra refrigeration or PC equipment. In view of safety concerns the integrated
cooling system uses no methanol or other inflammable and volatile cooling
fluids. The instrument is controlled using a touchscreen interface. Calibration
can be achieved with a single low temperature viscosity standard and sample
volume required is also kept to a minimum.While still retaining its small
footprint the standard CS-2 has now been integrated with the Ravenfield Model
DR AutoSampler which allows automatic measurement of up to 18 oil samples
without further operator intervention.
Model CS-2W If a
"budget" model be required the CS-2W option is available. The CS-2W is
functionally identical to the CS-2 except for the absence of the AutoSampler
which can of course be retrofitted if required. The retrofitting of the
AutoSampler could even be carried out by the customer in their own laboratory
in about thirty minutes.
|
| |
 |
|
|