Search
site |
|
| |
|
|
| |
|
|
 |
|
 |
|
| |
| Petroleum Testing |
|
|
|
A whole selection of
petroleum test equipment to ASTM standards. |
|
|
|
|
Portable Octane
analysers |
|
|
|
|
Chlorine analysers
& Sulfur analysers |
|
| Cement/Core PVT
Testing |
|
Core analysis,
petrophysics & rock mechanicss |
|
|
|
|
PVT, porrositmeters,
cement testing equipments |
|
|
|
|
Core flood analysis
equipments |
|
| Refinery analysers |
|
|
|
Specialising in on-line
analytical instrumentation for oil, gasindustries s |
|
| Scientific
Equipment |
|
|
|
Specialising in high precision viscometers, rheometers and
other scientific instruments |
|
|
|
|
|
|
|
|
Various specialist gas
generators |
|
|
|
|
UV spectrophotometers/
Microwave digestion/ spectrometers |
|
| Building
products |
|
|
|
Middle East agents for
bricks and paviours |
|
| Publications |
|
|
|
Global magazine/ periodical subscription
service |
|
| Health and
safety |
 |
Back supports |
|
|
Mindex Ltd back support reduce back injury in the
workplace |
|
| Petrochemicals |
|
|
|
Chemical marker for petroleum based
products. |
|
|
|
| |
| |
|
|
 |
|
| |
 |
| |
STANDARD
SPECIFICATION:
- Compact
Manually Operated System & RS 232 Data Output.
- Stiff
and Low Dead Volume Components for constant System Volume during Pressure
Cycles.
- 100psig
or 200psgi Helium Charge Pressure in Reference Volumes ( Vr) (specify pressure
with order).
- Micro
and Small Size Cup for Cuttings and Unconsolidated Grains Supplied with
Handling Tools.
- Large
range sample size accommodated from cuttings, via Ø1.13(28.8mm ) x 4
(101.6mm) to Ø1.63 (41.5mm ) x 4 (101.6mm). i.e.. Unconsolidated Cores
with Teflon heat shrink.
- High
Tensile St. St. Matrix Cup with Air Gap below Nylon Liner
Insulation.
- Graded
Volume High Accuracy Calibrated High Tensile Stainless St. Pack-out Billets in
carrying case.
- Helium
Leak Tight ¼ Turn Diaphragm Valves.
- 3
Reference Volumes (Vr-A, B & C ).
- Replaceable Sintered Stainless Steel Filters in 3 Places to Protect
Valve Integrity.
- High
Degree of Insulation to Reference Volumes and Pressure Transducer.
- Easy
Access to all Sites for Leak Checking and Repair.
- Ø
¼ Copper Coil for Fast Vr Pressure Charge up and Temperature
Equilibration.
SENSORS AND GAUGES:
- Pressure Transducer: Accuracy (Combined effects of Non-linearity,
Hysteresis and Repeatability) +/- 0.04 % FS BSL (maximum).
- Panel
Meter: 6 digits with RS 232 to Data Acquisition Module and Reduction/Analysis
Program.
- Gas
Temperature : PT 100 Grade A 0.1°C accuracy and 0.01°C
resolution.
SERVICE REQUIREMENTS:
- Standard Unit Process Gas: Regulated Helium Gas to 100 psig (7barg)
or 200psig (14barg) (maximum).
- Optional Model Process Gas: Helium Gas to 3000psig (207barg)
(maximum) to inlet port connector.
- Matrix
Cup Loading Frame Actuator Pressure: 145 psig (10barg) compressed air (Caution!
Must be set to this Value for on Gauge Safe Operation.
PHYSICAL DATA:
- Power
Supply: 240 Vac, 50 Hz, 1Ph.
- Dimensions (Standard Unit): 430 mm x 250 mm x 200 mm
- Weight